home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 08333wmm.txt < prev    next >
Text File  |  1998-06-10  |  11KB  |  291 lines

  1.                          SECTION 08333
  2.  
  3.               OVERHEAD COILING WOOD COUNTER DOORS
  4.  
  5. NOTE ** This section is based on products manufactured by
  6. NOTE ** Woodfold-Marco Mfg., Inc., at the following
  7.         address:
  8. NOTE **     P.O. Box 346
  9. NOTE **     Forest Grove OR 97116
  10. NOTE **     Tel: (503) 357-7181
  11. NOTE **     Fax: (503) 357-7185
  12. NOTE **
  13. NOTE ** Woodfold-Marco overhead coiling wood counter doors
  14.         offer an attractive solution when both security
  15.         requirements and aesthetic requirements must be
  16.         met.
  17. NOTE **
  18. NOTE ** SECTION 08333 - OVERHEAD COILING WOOD COUNTER
  19.         DOORS, Copyright 1998, The Architect's Catalog,
  20.         Inc.
  21.  
  22. PART 1  GENERAL
  23.  
  24. 1.1 SECTION INCLUDES
  25. NOTE ** Delete items below not required for project.
  26.  
  27.     A.  Overhead Coiling Wood Counter Doors.
  28.  
  29.     B.  Mechanical Operators.
  30.  
  31.     C.  Electrical Operators.
  32.  
  33. 1.2 RELATED SECTIONS
  34. NOTE ** Delete any sections below not relevant to this
  35.         project; add others as required.
  36.  
  37.     A.  Section 06100 - Rough Carpentry.
  38.  
  39.     B.  Section 06200 - Finish Carpentry.
  40.  
  41.     C.  Section 08710 - Door Hardware.
  42.  
  43.     D.  Section 09900 - Paints and Coatings.
  44.  
  45.     E.  Section 16050 - Basic Electrical Materials and Methods.
  46.  
  47. 1.3 SYSTEM DESCRIPTION
  48. NOTE ** Edit the following paragraph for project
  49.         requirements; if more than one type counter door is
  50.         required, add a Counter Door Type designation to
  51.         the first sentence, copy paragraph for as many
  52.         counter door types required, and edit each
  53.         paragraph accordingly.  Coordinate requirements
  54.         specified in this Article with items in COMPONENTS
  55.         Article of PART 2.
  56.  
  57.     A.  Design Requirements:
  58. NOTE ** Counter doors are available in Oak, Maple, Birch,
  59.         Mahogany, and Cherry; other species can be
  60.         specified also.  Consult manufacturer for options.
  61.         1.  Counter door wood species:  _________________.
  62. NOTE ** Delete all but one of the following three
  63.         sentences.
  64.         2.  Counter door mounting:  Inside mount, with coil and
  65.             guide rails mounted between opening jambs.
  66.         3.  Counter door mounting:  Mixed mount, with coil
  67.             mounted on face of wall, and guide rails mounted
  68.             between opening jambs.
  69.         4.  Counter door mounting:  Outside mount, with coil
  70.             mounted on face of wall, and guide rails mounted on
  71.             face of wall at jambs.
  72. NOTE ** Delete all but one of the following three
  73.         sentences.  Crank or motor operators are available
  74.         for large openings.  Specify handing requirements
  75.         for mechanical or electrical operator.
  76.         5.  Counter door operation:  Manual push-up.
  77.         6.  Counter door operation:  Manual crank operator, crank
  78.             socket on _____-hand side of counter door as viewed
  79.             from coil side.
  80.         7.  Counter door operation:  Electric motor operator on
  81.             _____-hand side of counter door as viewed from coil
  82.             side.
  83.         8.  Opening size:  Indicated on drawings.
  84.  
  85. 1.4 SUBMITTALS
  86.  
  87.     A.  Submit under provisions of Section 01300.
  88. NOTE ** Delete all but one of the following three
  89.         paragraphs:
  90. NOTE ** First paragraph is for counter door with motor
  91.         operator.
  92. NOTE ** Second paragraph is for counter door with crank
  93.         operator.
  94. NOTE ** Third paragraph is for push-up operated counter
  95.         door.
  96.  
  97.     B.  Product Data:  Manufacturer's descriptive literature for
  98.         counter door units, hardware, operators and controls;
  99.         include power requirements.
  100.  
  101.     C.  Product Data:  Manufacturer's descriptive literature for
  102.         counter door units, hardware, and operators.
  103.  
  104.     D.  Product Data:  Manufacturer's descriptive literature for
  105.         counter door units and hardware.
  106. NOTE ** Delete one of the following two paragraphs:
  107. NOTE ** First paragraph is for counter door with motor
  108.         operator.
  109. NOTE ** Second paragraph is for counter door with crank
  110.         operator or push-up operated counter door.
  111.  
  112.     E.  Shop Drawings:  Indicate opening sizes, jamb, sill, and
  113.         head conditions, control locations, and required
  114.         locations for power source.
  115.  
  116.     F.  Shop Drawings:  Indicate opening sizes, jamb, sill, and
  117.         head conditions.
  118. NOTE ** Delete the following paragraph if specifying custom
  119.         species.
  120.  
  121.     G.  Selection Samples:  Two sets of wood species samples,
  122.         representing manufacturer's full range of available
  123.         species selection.
  124. NOTE ** Delete one of the two following paragraphs; second
  125.         paragraph is for factory-finished assembly.
  126.  
  127.     H.  Verification Samples:  Two sample curtain slats, minimum
  128.         size 8 inches in length, representing actual species and
  129.         grain quality of installed product.
  130.  
  131.     I.  Verification Samples:  Two sample curtain slats, minimum
  132.         size 8 inches in length, representing actual species,
  133.         grain quality, and match to specified factory finish, of
  134.         installed product.
  135.  
  136.     J.  Quality Assurance Submittals:  Printed installation
  137.         instructions for specified counter door assembly.
  138.  
  139. 1.5 DELIVERY, STORAGE, AND HANDLING
  140.  
  141.     A.  Storage and Protection:
  142.         1.  Store components in manufacturer's unopened packaging
  143.             until installation.
  144.         2.  Maintain dry, heated storage area for components
  145.             installation.
  146.  
  147.  
  148. PART 2  PRODUCTS
  149.  
  150. 2.1 MANUFACTURERS
  151.  
  152.     A.  Acceptable Manufacturer:  Woodfold-Marco Mfg., Inc.; P.O.
  153.         Box 346, Forest Grove OR 97116; ASD. Tel: (503) 357-7181,
  154.         Fax: (503) 357-7185.
  155. NOTE ** Delete one of the two following paragraphs;
  156.         coordinate with Division 01 requirements.
  157.  
  158.     B.  Requests for substitutions will be considered in
  159.         accordance with provisions of Section 01600.
  160.  
  161.     C.  Substitutions:  Not permitted.
  162.  
  163. 2.2 COMPONENTS
  164.  
  165.     A.  Curtain:
  166.         1.  Slats:  Solid hardwood profiles with long edges
  167.             rabbeted to interlock to form sight-proof curtain.
  168.         2.  Bottom rail:  Solid wood profile matching grain and
  169.             species of slat.
  170.         3.  Interlocking hardware:  Manufacturer's standard,
  171.             concealed within slat and bottom rail profile.
  172.  
  173.     B.  Guides:  Manufacturer's standard guides for indicated
  174.         counter door mounting and operation.
  175. NOTE ** Delete the following paragraph if not required.
  176.  
  177.     C.  Operator:  Geared lifting and lowering mechanism with
  178.         manual crank operator.
  179. NOTE ** Delete the following two paragraphs if not
  180.         required.
  181.  
  182.     D.  Operator:  Tubular electric motor operator, 110VAC 60Hz
  183.         power requirement.
  184.  
  185.     E.  Operating Switch:  Specified in Section 16050.
  186. NOTE ** Retain the following paragraph if specifying crank
  187.         or motor operation and inside or mixed mounting.
  188.  
  189.     F.  Guide Spacers:  Manufacturer's standard spacers to allow
  190.         clearance for gear box.
  191. NOTE ** Edit the following three paragraphs for latching
  192.         requirements.  Delete all three paragraphs if
  193.         specifying electric operation.
  194.  
  195.     G.  Latching Hardware:  Manufacturer's standard sidebolt
  196.         surface mounted to curtain bottom rail at each end of
  197.         curtain.
  198.  
  199.     H.  Latching Hardware:  Deadbolt with thumbturn, mortised
  200.         into curtain bottom rail on coil side of counter door.
  201.  
  202.     I.  Latching Hardware:
  203.         1.  Deadbolt with keylock, mortised into curtain bottom
  204.             rail on coil side of counter door.
  205. NOTE ** Delete one of the following paragraphs; first
  206.         paragraph applies if manufacturer supplies
  207.         cylinders for locksets, second applies if cylinders
  208.         for entire project are specified in Section 08710.
  209.         2.  Supply two (2) keys for each lock.
  210.         3.  Cylinders for keylocks are specified in Section
  211.             08710.
  212. NOTE ** Retain one or both of the following paragraphs if
  213.         coil will be sight-exposed in the finished Work.
  214.  
  215.     J.  Hood:  Constructed of plywood, with veneer on sight-
  216.         exposed face matching species of curtain material, or
  217.         solid wood of same species as curtain material; concealed
  218.         fastener construction to facilitate hood removal for
  219.         servicing counter door.
  220.  
  221.     K.  Fascia:  Constructed of plywood, veneer on sight-exposed
  222.         face matching species of curtain materials; concealed
  223.         fastener attachment to facilitate fascia removal for
  224.         servicing counter door.
  225.  
  226. 2.3 FINISHES
  227.  
  228.     A.  Sand sight-exposed wood surfaces to smooth finish.
  229. NOTE ** Delete all but one of the following three
  230.         paragraphs.
  231. NOTE **
  232. NOTE ** Woodfold specializes in the factory finishing of
  233.         components, using only environmentally safe
  234.         finishing materials; factory finishing eliminates
  235.         problems associated with handling of unfinished
  236.         hardwood surfaces, and with time delays associated
  237.         with site finishing.
  238. NOTE **
  239. NOTE ** If specifying custom finish in third paragraph,
  240.         consult with manufacturer of counter door and
  241.         manufacturer of finish material to specify
  242.         finishing technique correctly.
  243.  
  244.     B.  Application of final finish is specified in Section
  245.         09900.
  246.  
  247.     C.  Apply clear polyurethane sealer to sight-exposed wood
  248.         surfaces.
  249.  
  250.     D.  Custom Finish:  ___________________.
  251.  
  252.  
  253. PART 3  EXECUTION
  254.  
  255. 3.1 EXAMINATION
  256.  
  257.     A.  Verification of Conditions:  Verify openings are in
  258.         accordance with approved shop drawings.
  259.  
  260.     B.  Installer's Examination:
  261.         1.  Have installer of this section examine conditions
  262.             under which construction activities of this section
  263.             are to be performed, then submit written notification
  264.             if such conditions are unacceptable.
  265.         2.  Transmit two copies of installer's report to
  266.             Architect within 24 hours of receipt.
  267.         3.  Beginning construction activities of this section
  268.             before unacceptable conditions have been corrected is
  269.             prohibited.
  270.         4.  Beginning construction activities of this section
  271.             indicates installer's acceptance of conditions.
  272.  
  273. 3.2 INSTALLATION
  274.  
  275.     A.  Install counter doors plumb and level in accordance with
  276.         approved shop drawings and manufacturer's printed
  277.         installation instructions.
  278. NOTE ** Delete the following paragraph if electric operator
  279.         is not specified.
  280.  
  281.     B.  Installation of switch operator and connection of
  282.         electrical components are specified in Section 16050.
  283.  
  284. 3.3 ADJUSTING
  285.  
  286.     A.  Adjust counter doors to operate correctly in accordance
  287.         with manufacturer's product data.
  288.  
  289.  
  290.                          END OF SECTION