SECTION 08333
OVERHEAD COILING WOOD COUNTER DOORS
NOTE ** This section is based on products manufactured by
NOTE ** Woodfold-Marco Mfg., Inc., at the following
address:
NOTE ** P.O. Box 346
NOTE ** Forest Grove OR 97116
NOTE ** Tel: (503) 357-7181
NOTE ** Fax: (503) 357-7185
NOTE **
NOTE ** Woodfold-Marco overhead coiling wood counter doors
offer an attractive solution when both security
requirements and aesthetic requirements must be
met.
NOTE **
NOTE ** SECTION 08333 - OVERHEAD COILING WOOD COUNTER
DOORS, Copyright 1998, The Architect's Catalog,
Inc.
PART 1 GENERAL
1.1 SECTION INCLUDES
NOTE ** Delete items below not required for project.
A. Overhead Coiling Wood Counter Doors.
B. Mechanical Operators.
C. Electrical Operators.
1.2 RELATED SECTIONS
NOTE ** Delete any sections below not relevant to this
project; add others as required.
A. Section 06100 - Rough Carpentry.
B. Section 06200 - Finish Carpentry.
C. Section 08710 - Door Hardware.
D. Section 09900 - Paints and Coatings.
E. Section 16050 - Basic Electrical Materials and Methods.
1.3 SYSTEM DESCRIPTION
NOTE ** Edit the following paragraph for project
requirements; if more than one type counter door is
required, add a Counter Door Type designation to
the first sentence, copy paragraph for as many
counter door types required, and edit each
paragraph accordingly. Coordinate requirements
specified in this Article with items in COMPONENTS
Article of PART 2.
A. Design Requirements:
NOTE ** Counter doors are available in Oak, Maple, Birch,
Mahogany, and Cherry; other species can be
specified also. Consult manufacturer for options.
1. Counter door wood species: _________________.
NOTE ** Delete all but one of the following three
sentences.
2. Counter door mounting: Inside mount, with coil and
guide rails mounted between opening jambs.
3. Counter door mounting: Mixed mount, with coil
mounted on face of wall, and guide rails mounted
between opening jambs.
4. Counter door mounting: Outside mount, with coil
mounted on face of wall, and guide rails mounted on
face of wall at jambs.
NOTE ** Delete all but one of the following three
sentences. Crank or motor operators are available
for large openings. Specify handing requirements
for mechanical or electrical operator.
5. Counter door operation: Manual push-up.
6. Counter door operation: Manual crank operator, crank
socket on _____-hand side of counter door as viewed
from coil side.
7. Counter door operation: Electric motor operator on
_____-hand side of counter door as viewed from coil
side.
8. Opening size: Indicated on drawings.
1.4 SUBMITTALS
A. Submit under provisions of Section 01300.
NOTE ** Delete all but one of the following three
paragraphs:
NOTE ** First paragraph is for counter door with motor
operator.
NOTE ** Second paragraph is for counter door with crank
operator.
NOTE ** Third paragraph is for push-up operated counter
door.
B. Product Data: Manufacturer's descriptive literature for
counter door units, hardware, operators and controls;
include power requirements.
C. Product Data: Manufacturer's descriptive literature for
counter door units, hardware, and operators.
D. Product Data: Manufacturer's descriptive literature for
counter door units and hardware.
NOTE ** Delete one of the following two paragraphs:
NOTE ** First paragraph is for counter door with motor
operator.
NOTE ** Second paragraph is for counter door with crank
operator or push-up operated counter door.
E. Shop Drawings: Indicate opening sizes, jamb, sill, and
head conditions, control locations, and required
locations for power source.
F. Shop Drawings: Indicate opening sizes, jamb, sill, and
head conditions.
NOTE ** Delete the following paragraph if specifying custom
species.
G. Selection Samples: Two sets of wood species samples,
representing manufacturer's full range of available
species selection.
NOTE ** Delete one of the two following paragraphs; second
paragraph is for factory-finished assembly.
H. Verification Samples: Two sample curtain slats, minimum
size 8 inches in length, representing actual species and
grain quality of installed product.
I. Verification Samples: Two sample curtain slats, minimum
size 8 inches in length, representing actual species,
grain quality, and match to specified factory finish, of
installed product.
J. Quality Assurance Submittals: Printed installation
instructions for specified counter door assembly.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Storage and Protection:
1. Store components in manufacturer's unopened packaging
until installation.
2. Maintain dry, heated storage area for components
installation.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Woodfold-Marco Mfg., Inc.; P.O.
Box 346, Forest Grove OR 97116; ASD. Tel: (503) 357-7181,
Fax: (503) 357-7185.
NOTE ** Delete one of the two following paragraphs;
coordinate with Division 01 requirements.
B. Requests for substitutions will be considered in
accordance with provisions of Section 01600.
C. Substitutions: Not permitted.
2.2 COMPONENTS
A. Curtain:
1. Slats: Solid hardwood profiles with long edges
rabbeted to interlock to form sight-proof curtain.
2. Bottom rail: Solid wood profile matching grain and
species of slat.
3. Interlocking hardware: Manufacturer's standard,
concealed within slat and bottom rail profile.
B. Guides: Manufacturer's standard guides for indicated
counter door mounting and operation.
NOTE ** Delete the following paragraph if not required.
C. Operator: Geared lifting and lowering mechanism with
manual crank operator.
NOTE ** Delete the following two paragraphs if not
required.
D. Operator: Tubular electric motor operator, 110VAC 60Hz
power requirement.
E. Operating Switch: Specified in Section 16050.
NOTE ** Retain the following paragraph if specifying crank
or motor operation and inside or mixed mounting.
F. Guide Spacers: Manufacturer's standard spacers to allow
clearance for gear box.
NOTE ** Edit the following three paragraphs for latching
requirements. Delete all three paragraphs if
specifying electric operation.
G. Latching Hardware: Manufacturer's standard sidebolt
surface mounted to curtain bottom rail at each end of
curtain.
H. Latching Hardware: Deadbolt with thumbturn, mortised
into curtain bottom rail on coil side of counter door.
I. Latching Hardware:
1. Deadbolt with keylock, mortised into curtain bottom
rail on coil side of counter door.
NOTE ** Delete one of the following paragraphs; first
paragraph applies if manufacturer supplies
cylinders for locksets, second applies if cylinders
for entire project are specified in Section 08710.
2. Supply two (2) keys for each lock.
3. Cylinders for keylocks are specified in Section
08710.
NOTE ** Retain one or both of the following paragraphs if
coil will be sight-exposed in the finished Work.
J. Hood: Constructed of plywood, with veneer on sight-
exposed face matching species of curtain material, or
solid wood of same species as curtain material; concealed
fastener construction to facilitate hood removal for
servicing counter door.
K. Fascia: Constructed of plywood, veneer on sight-exposed
face matching species of curtain materials; concealed
fastener attachment to facilitate fascia removal for
servicing counter door.
2.3 FINISHES
A. Sand sight-exposed wood surfaces to smooth finish.
NOTE ** Delete all but one of the following three
paragraphs.
NOTE **
NOTE ** Woodfold specializes in the factory finishing of
components, using only environmentally safe
finishing materials; factory finishing eliminates
problems associated with handling of unfinished
hardwood surfaces, and with time delays associated
with site finishing.
NOTE **
NOTE ** If specifying custom finish in third paragraph,
consult with manufacturer of counter door and
manufacturer of finish material to specify
finishing technique correctly.
B. Application of final finish is specified in Section
09900.
C. Apply clear polyurethane sealer to sight-exposed wood
surfaces.
D. Custom Finish: ___________________.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verification of Conditions: Verify openings are in
accordance with approved shop drawings.
B. Installer's Examination:
1. Have installer of this section examine conditions
under which construction activities of this section
are to be performed, then submit written notification
if such conditions are unacceptable.
2. Transmit two copies of installer's report to
Architect within 24 hours of receipt.
3. Beginning construction activities of this section
before unacceptable conditions have been corrected is
prohibited.
4. Beginning construction activities of this section
indicates installer's acceptance of conditions.
3.2 INSTALLATION
A. Install counter doors plumb and level in accordance with
approved shop drawings and manufacturer's printed
installation instructions.
NOTE ** Delete the following paragraph if electric operator
is not specified.
B. Installation of switch operator and connection of
electrical components are specified in Section 16050.
3.3 ADJUSTING
A. Adjust counter doors to operate correctly in accordance
with manufacturer's product data.
END OF SECTION